Temperature measurement

 SITRANS T: the complete range of temperature measurement devices

 

 

Whatever you are looking for in a temperature transmitter, SITRANS T temperature measurement devices are your solutions; they can be quickly connected to many different thermocouples and resistance thermometers, as well as mV and resistance sensors. The SITRANS T temperature transmitter range works using galvanic isolation and a selectable network frequency and is available as intrinsically safe, explosion proof and non-sparking versions and also as non-hazardous versions.

 

Product overview

 

 

SITRANS TH100

Temperature Measurement | Head Transmitter

SITRANS TH100 is rigid designed for economic use. For example with saving of the galvanic insulation, which is not need for PT100. Therefore the TH100 offers economic plant operation and reliable measurements. It is an ideal substitute for over aged analogue PT100 transmitters. Setup is quick and easy with the transmitter-modem and SIPROM T.

Input

 Pt 100 resistance

Output

 4 to 20 mA

 

SITRANS TH200

Temperature Measurement | Head Transmitter

SITRANS TH200 is designed to support all common RTDs, thermocouples, resistance and millivolt-sensors. Setup is quick and easy with the transmitter-modem and SIPROM T software.

Input

Resistance thermometers, Thermocouples, Resistance-type sensors, DC sources

Output

4 to 20 mA

   
   
SITRANS TH300

Temperature Measurement | Head Transmitter

SITRANS TH300 with HART- protocol is designed to support all common thermocouples, resistance and millivolt sensors. Setup is quick and easy with SIMATIC PDM or handheld communicator.

Input

Resistance thermometers, Thermocouples, Resistance-type sensors, DC sources

Output

4 to 20 mA, HART

   
   
SITRANS TH400 

Temperature Measurement | Head Transmitter

SITRANS TH400 is available either with PROFIBUS PA or FOUNDATION Fieldbus (FF). It is designed to support all common RTD, thermocouple, resistance and millivolt sensors. Setup is quick and easy with SIMATIC PDM(PA) or AMS and handheld communicator(FF). Due to its small size, the device allows flexible mounting options, even in a DIN Type B connection head.

Input

Resistance thermometers, Thermocouples, Resistance-type sensors, DC sources

Output

PROFIBUS PA (variant), Foundation Fieldbus (variant)

   

 

 

SITRANS TR200

Temperature Measurement | Rail Transmitter

SITRANS TR200 is designed to support all common RTDs, thermocouples, resistance and Millivolt sensors. Setup is quick and easy with the transmitter-modem and SIPROM T software.

Input

Resistance thermometers, Thermocouples, Resistance-type sensors, DC sources

Output

4 to 20 mA

   
   

 

SITRANS TR300

Temperature Measurement | Rail Transmitter 

SITRANS TR300 with HART- protocol is designed to support all commons, thermocouples, resistance and Millivolt sensors. Setup is quick and easy with SIMATIC PDM or handheld communicator. Unique user-friendly details are implemented: Without opening the 4-20mA loop the output current can be read out directly with a multimeter. A red/green LED shows the technician the status at a glance.

Input

Resistance thermometers, Thermocouples, Resistance-type sensors, DC sources

Output

4 to 20 mA, HART

 

SITRANS TW

Temperature Measurement | Rail Transmitter

SITRANS TW is a consistent further development of the hundred thousand times proven SITRANS T for the 4wire system in the mounting rail housing. Its many new functions set new standards in temperature transmitters. Its diagnostic and simulation functions provide the necessary clarity during commissioning and operation. Its HART®-interface makes the SITRANS TW easily adaptable to any measuring job with SIMATIC PDM.

Physical values can be preset with the simulation function. This enables testing of the complete signal path right as far as the control system without the need for tools. The drag pointer functions measure the system’s process variable minimum and maximum.

Input

Resistance thermometers, Thermocouples, Resistance-type sensors, DC sources, Current sources

Output

0/4 to 20 mA, HART

0/2 to 10 V, HART

SITRANS TF

Temperature Measurement | Field Transmitter

SITRANS TF is used where other transmitters can't cope. One main point is its rating of IP67.

SITRANS TF is made of rugged die cast aluminum or long-lasting stainless steel. It transforms resistance thermometers, thermocouples, Ohm and mV signals into a load independent DC current corresponding to sensor characteristic or a digital signal according Fieldbus standard Profibus PA or Foundation Fieldbus. The remote mounted sensor prevents the transmitter heating up at high temperature; there are no vibrations and oscillations due to long neck tubes and protective pipes with SITRANS TF.

 Input

Resistance thermometers, Thermocouples, Resistance-type sensors, DC sources

 Output

Versions for:

4 to 20 mA, 4...20 mA with HART, Profibus PA or Foundation Fieldbus

 

SITRANS TF280

Temperature Measurement | Field Transmitter

The SITRANS TF280 is a WirelessHART temperature transmitter that provides all measured process values as well as diagnostic information, parameters and functions via radio. The device is powered by an internal battery and designed for ultra low power consumption. Its compact and rugged design makes it specially suitable for direct mounting on tanks and pipes in remote parts of plants, and on moving or rotating equipment for process monitoring or asset management applications.

Input

Pt100 (IEC 60751)

Output

WirelessHART radio in 2.4 GHz

   
   

« Back to Process Instrumentation